Appendix G |
||
|
Title: SUPPLEMENTAL REQUIREMENTS FOR GENERAL
MATERIAL DDG 51 ARLEIGH BURKE CLASS and DDG
1000 ZUMWALT CLASS |
Rev. R |
Date 9/18/07 |
|
|
|
|
||
|
SDRL CODE: E001,
DRAWINGS: |
|||
|
a. Provide 2 copies of drawings showing the
following for review and approval in accordance with the delivery schedule
shown on the P.O. - Title block including drawing number,
revision, date and manufacturer’s name. - Outline with overall envelope dimensions. - Maintenance access envelopes. - Location, type and size of interface
connections to piping, cabling, foundation, etc. - Weight both with and without operating
fluids, if applicable. - Center of gravity both with and without
operating fluids. - List of material with quantity and
specifications. - Sectional assembly identifying parts. - Electrical and hydraulic schematic
diagrams. b. Drawings shall be 8-1/2” x 11” size or
folded individually in accordian pleated form to an
8-1/2” x 11” size with title block exposed in the lower right hand corner. c. If for any reason there is a change to the
configuration of the material, 2 copies of the revised drawings shall be
submitted within 30 days. d. For equipment that is identical to
equipment previously provided by the Seller, and for which the Seller has
previously provided drawings, the Seller may choose to submit a certificate
of identicality (COI) rather than resubmit the
drawings. The COI shall be submitted
on the form provided at the end of this appendix. |
|||