Bath Iron Works

                        

A GENERAL DYNAMICS COMPANY

                         Appendix G

Title:

SUPPLEMENTAL REQUIREMENTS FOR GENERAL MATERIAL

 

DDG 51 ARLEIGH BURKE CLASS and DDG 1000 ZUMWALT CLASS

Rev.

S

Date

3/20/08

 

APPENDIX G HOME

 

REVISION HISTORY

 

 

SDRL CODE:  QCOD, CALIBRATION CERTIFICATE:

a.   The Seller shall accomplish the requirement of ANSI Z540-1-1994, Calibration Laboratories and Measuring and Test Equipment-General Requirements.

 

b.   Two legible copies of the Certificate of Calibration, Figure 4, shall be provided with each packing list.  Certificate shall be completed and signed by a responsible representative of the Seller.

 

c.   Two legible copies of the Calibration Data Sheets shall also be provided by Seller with each packing list to indicate functions tested, nominal and measured values, and calibration tolerances.

 

--------------------------------------------------------------------------------------------------------------------

                                     CALIBRATION CERTIFICATE                       Printable .pdf Version

 

I hereby certify that the instrument(s) listed below have been examined, tested and found to be within the manufacturer’s published specification when compared with standard instruments.

 

Calibration of all standard instruments used on performance of the above tests is traceable to  the National Bureau of Standards.  The standards and instruments used in the calibration are supported by a calibration system that meets or exceeds the requirements of ANSI Z540-1-1994.

 

Signed                   

Title                    

Company                  

 

Mfr:                                      Item Part #              

Purchase Order #                          Item Serial #            

Line Item                                 Calibration Data         

BIW Catalog #                             Calibration Due Data     

Item Nomen.                      

 

National Bureau of Standards Test No.                              

 

 

Figure (4)      Calibration Certificate    Figure (4)